GC&耗材&备件-全新美国SRI GC
 

BRAND NEW Multiple Gas Analyzer #2 GC system

The Multiple Gas Analyzer #2 GC system (MG#2) is pre-plumbed and ready to resolve H2, O2, N2, methane, CO, ethane, CO2, ethylene, NOx, water, alcohols, propane, butanes, pentanes and C6+. The MG#2 is similar to the MG#1, except that the MG#2 can measure water and alcohol in addition to the multiple gas compounds.

To separate such a wide variety of peaks without co-elution, the MG#2 turns on the carrier gas flow to each column at different times during the run. This allows the Molecular Sieve column to complete the separation of H2, O2, N2, CH4 and CO, at which point the MoleSieve carrier flow is turned off and the HayeSep-D carrier flow is turned on. The HayeSep-D column then separates all compounds in the C1-C6 range. A capillary column in parallel with the HayeSep-D can also be useful in separating the hydrocarbons out through C20. Detectors can be TCD, HID, FID, or any combination, depending on your application needs.

Features:

  • Separates multiple gases with a single injection
  • Very tolerant of user adjustments and timing variations
  • Simpler than other multiple gas capable systems
  • TCD Detector
  • MoleSieve 13X & HayeSep-D Columns
  • 10-port Gas Sampling Valve and Dual Loops
  • 1 channel PeakSimple Data System on the compact 8610C chassis

Includes TWO (2) YEAR WARRANTY. Does not include computer or monitor - requires Win 95 or newer.

(VOLTAGE: for 110VAC, use "part number-1" [ex: 8610-0270-1] for 220VAC, use "part number-2")

Options & Upgrades:

  • Multiple Gas Analyzer #2 with TCD, Methanizer, FID, built-in "whisper quiet" air compressor, and 4 channel PeakSimple data system
  • Multiple Gas Analyzer #2 with TCD and HID detectors, and 4 channel PeakSimple data system
  • 6 channel USB PeakSimple data system
  • H2-50XR hydrogen generator
  • additional gas sampling valve
  • additional detectors
  • additional columns

This chromatogram shows the separation of a 1% Gas Standard sample on a MG#2 eqipped with a TCD detector. The first five peaks came off the MoleSieve column, and the following three peaks came off the HayeSep-D column. Note that the methane elutes twice, once from each column.


 
 
 