Waters 2790 Alliance

This Waters 2790 Alliance is in excellent condition and has been fully tested at GenTech Scientific. It is an integrated solvent and sample management platform which combines two traditional high-performance liquid chromatography (HPLC) components: a solvent management system and a sample management system. Includes NINETY (90) DAY WARRANTY.

Physical Specifications

  • Height: 22.5 in. (57 cm)
  • Depth: 23.5 in. (60 cm)
  • Width: 23 in. (58 cm)
  • Weight: 136 lb. (62 kg)
  • Wetted Surface Materials: 316 stainless steel, UHMWPE, sapphire, ruby, Tefzel® (ETFE), Teflon® (FEP and PTFE), PEEK, Fluoroloy G, Fluoroloy–08R

Environmental Specifications

  • Operating Temperature 4 to 40° C
  • Relative Humidity 20 to 80%, noncondensing
  • Acoustic Noise <65 dB(A)

Solvent Management System Specifications

  • Number of Solvents: One to four, three with vacuum degas
  • Solvent Conditioning: Vacuum degas, three solvents plus purge solvent
  • Typical Operating Flow Rate Range: 0.050 to 5.000 mL/min in 0.001-mL/min increments
  • Programmable Flow Rate Range: 0.000 and 0.010 to 10.000 mL/min in 0.001-mL/min increments
  • Compressibility Compensation: Automatic and continuous
  • System Delay Volume: <400 µL, independent of backpressure, 1 mL/min
  • Plunger Seal Wash: Integral, active, programmable
  • Gradient Profiles: Eleven (11) gradient curves [including linear, step (2 curves), concave (4 curves), and convex (4 curves)]
  • Dry Prime/Wet Prime: Automatic, front panel control
  • Flow Ramping: Time (0.01 to 30.00 min in 0.01-min increments) to reach maximum flow rate
  • Maximum Operating Pressure: 5000 psi (345 bar) at 0.010 to 3.000 mL/min; Programmable upper and lower limits
  • Composition Range: 0.0 to 100.0% in 0.1% increments
  • Composition Accuracy: ±0.5% absolute, independent of backpressure (Proportioning Valve Pair Test [degassed methanol: methanol/propylparaben, 2 mL/min, 257 nm])
  • A Composition Precision: <=0.15% RSD o r<=0.02 min SD, whichever is greater, based on retention time. (Degassed 60% methanol:40% water Dial-a-Mix, 1 mL/min, six replicates, phenone mix, 257 nm)
  • Flow Precision: <=0.075% RSD or <=0.02 min SD, whichever is greater, based on retention time (N = 6) or volumetric measures (0.200 to 5.000 mL/min), isocratic premix
  • Flow Accuracy: <=1% or 10 µL/min, whichever is greater, (0.200 to 5.000 mL/ min), degassed methanol, at 600 psi backpressure

Sample Management System Specifications

  • Number of Sample Plates: Total of four plates:
    - Microtiter plate – 96- or 384-well
    - Vial plate – 2.0-mL vial (48)
    - Tube plate – 0.5-mL microcentrifuge tube (48) or 1.5-mL microcentrifuge tube (24)
    - Open access plate – 2.0-mL vial (24 or 48)
  • Sample Temperature Control: 4 to 40° C, programmable in 1° C increments
  • Maximum Sample Capacity: 1536 in four 384-well plates
  • Number of Sample Injections: 1 to 99 injections per sample
  • Sample Delivery Precision: <0.3% RSD, full loop 50 µL. (Default wash/purge conditions, degassed 60% methanol: 40% water Dial-a-Mix, 1 mL/min, six replicates, paraben mix, 257 nm)
  • Sample Volume Linearity: >0.999% correlation, 5 to 20 µL, partial fill in 50-µL loop, 3-µL pre- and post-sample air gaps (Default wash/purge conditions, degassed 60% methanol:40% water Dial-a-Mix, 1 mL/min, six replicates, paraben mix, 257 nm)
  • Needle Wash Solvents: Two: wash (strong solvent) and purge (sample- compatible) solvent A
  • Sample Carryover: <0.01% or <2.5 nL (default wash/purge volumes), whichever is greater. (Blank injection, 25 µL, 60% methanol:40% water, after six replicates, 25 µL propylparaben, 1 g/L, 257 nm)

Instrument Control Specifications

  • Parallel Sample Processing: User-programmable next-sample aspiration and loop fill, column equilibration, just-in-time gradient delivery
  • Advanced Operations: Auto addition, sample pooling, open access, priority samples
  • Column Heater: 20° C (5° C above ambient) to 60° C, in 1° C increments

 


 
 
 
______________________________________________________________________________________